IDS 410HS
100 SAMPLES A SECOND
MULTI-FUNCTION INDICATOR
Download data sheet PDF format (218k)
PDF manual

APPLICATIONS     SPECIFICATIONS

PROGRAM MODES

The IDS 410HS is preprogrammed with 10 different modes of operation to accommodate most of the basic industrial scale applications with the speed and accuracy of 100 samples per second. The mode is selected and easily configured from the keyboard during initial setup. The unit will operate in the mode selected until the user reconfigures it.

MODE 0: Push-button tare.
Used for basic gross or net mode weighing.

MODE 1 : Keyboard tare.
Allows the user to keyboard enter a tare weight which can be used for net weight calculation.

MODE 2 : Accumulate with Running Total.
Accumulate gross or net weights and maintain running total for job, lot, etc. Calculates G,T,N, totals.

MODE 3 : Print Weight With Subtotal and Total.
You can print the lot or job or lot subtotal whenever needed. Totalized and clear at the end of the run.

MODE 4 : Manual (Axle) Weigh.
Push the PRINT button to sequentially number and print a series of weighments. Push the TOTAL button to print and clear the total and reset the sequence number.

MODE 5 : Automatic (Axle) weigh.
This mode operates similar to Mode 4 except printing is automatic when motion settles. Traffic light control, trip level selection, and delay times for control functions are provided.

MODE 6 : Automatic Axle weight On Long Scales.
Weigh by axle on a truck scale. weight on the scale is automatically tared off after each weihgment.Operation, controls and selections are the same as Mode 5.

MODE 7 : Peak Hold Mode.
Display and print the peak weight detected by the indicator in the gross or net mode.

MODE 8 : Over / Under Checkweigh.
Provides three TTL outputs and two setpoints. Outputs can be used with lights or alarms to indicate weight on the scale is over, under, or between setpoint weights.

MODE 9 : Bulkweigh.
Features a setpoint with remote start / stop option and fill control relay signal. Scale empty weight and draft weights are configurable. Use for multiple drafts with total and subtotal printing.

 

COMMUNICATIONS

Serial Port 1:     .................................     RS232 or 20ma current loop.
Serial Port 2:     .................................     RS232 or RS485.
Digital Port:       .................................     3 TTL inputs and 3 TTL outputs.

OPTIONS

Input power option:    12 to 28 VDC.

Analog Output:    Provides 4-20ma, 0-20ma, 0-24ma, 0-5v, 0-10v outputs with 16-bit resolution for process control.

Relay Module:    The relay module accommodates 3 optically-isolated input and or output, solid-state relays.

Time and Date module:    Y2K compliant clock.

SPECIFICATIONS

GENERAL SPEC.
Power:
120 VAC  ±10%, 50/60 Hz  or 10 to 28 VDC optional. Power supply is mounted internally. Ligtning protection for load cell and AC input lines is standard.

Power Consumption operating:   13 watts @ 115VAC, 20 watts @ 12VDC.

Operating Temperature:              -10 to +40 oC.

Size:                                             11" wide, 8" high, and 2" deep (28 x 20 x 5 cm).

Weight:                                        6 lbs (2.72 kg).

SCALE SPEC.
Display:  
................................     1-inch x 6-digit numeric, 5-LED status
                                                         indicators.
Keyboard:    ..........................      Sealed with tactile feel.
Display Graduations: .........      200,000 industrial; 10,000 HB44.
Display increments:    ........       1, 2, 5, 10, 20, 50.
Decimal Point:    ..................       0 to 4 decimal places.
Internal Graduations: ........        1,024,000.
Conversation Rate:    ........        100/sec. @ 60 HZ line frequency.
Signal Sensitivity:    ...........        0.1 uV/grad (min).
Signal Range: ...................          0.5 mv/V to 6mv/V
Load Cell Excitation:  .......        10 V
Load Cell Current:    .........         240 ma with eight 350 ohm load cells.
Auto Zero Tracking:    ......         0-60 grads @ 1/4 grad increments.
Auto Zero Delay:    ............         0-25 sec. @ 0.1 sec. increments.

Linerization: .......................         5 point.
Digital Filter:    ....................         Using advanced DSP algorithm.
Digital Calibration:    .......           Features front panel calibratin. Zero
                                                          and Span stored in EAROM.
Watchdog Timer:    .........            Fault tolerant operation.


Download data sheet PDF format (218k)


PDF manual